Kitchen Counter Outlets - The code requires two or more 20-ampere circuits for all receptacle outlets for the small-appliance loads, including refrigeration equipment, in your kitchen, dining area, pantry, and a bréakfast room of á dwelling unit. Thé countertop receptacle outlets in kitchens should be provided by no less than two little appliance bránch circuits. Thése circuits could also offer receptacle outlets in the pántry, dining area, and breakfast room, in addition to a power clock receptacle and electric loads connected with gas-fired devices, but thése circuits are tó haven't any other outlets. Surface fault protection is necessary for all boxes serving countertop surfaces. 

Kitchen Counter Outlets

No restriction is positioned on the number of outlets linked to a general-light or small-appliance branch circuit. Thé minimum number of receptacle outlets in a room depends upon 6-foot/ 12-foot rule based on the room perimeter. It may be desired to provide more than the minimum number of receptacle outlets required, thereby further reducing the need for extension cords. 


Exhibit 210.25 illustrates the application of the requirements. The small-appliance branch circuits illustrated are not permitted to serve any other outlets, such as may be connected to exhaust hoods or followers, disposals, or dishwashers. The countertop receptacles are also required to be provided by both of these circuits. Boxes set up to serve countertop surfaces are anticipated to be GFCI secured. The dining area switched container with a 15-ampere general-purpose branch circuit is indeed permitted. The refrigerator receptacle given by a 15-ampere specific branch circuit is certainly allowed. 

Important places Kitchen Counter Outlets

Wall Counter Areas: A receptacle outlet will be set up at each wall structure, counter space that's 300 mm (12 in.) or even more comprehensive. Receptacle outlets will be linked so that no point along the wall collection is more than 600 mm (24 in.) measured horizontally from a receptacle store in that space. 

  • Island Counter Spaces: At least one receptacle store shall be set up at each island counter spacé with an extended dimension of 600 mm (24 in.) or more and a short size of 300 mm (12 in.) or more. 
  • Peninsular Counter Spaces: At the least, one receptacle outlet will be installed at every peninsular counter space with an extended dimension of 600 mm (24 in.) or more and a short size of 300 mm (12 in.) or more. A peninsular countertop is measured from the connecting edge. 
  • Separate Spaces: Countertop spaces separated by rangé tops, refrigerators, ór sinks shall be considered as different countertop spaces in applying the requirements.
  • Receptacle Outlet Location: Receptacle outlets shall be located above, but not more than 500 mm (20 in.) above, the countertop. Receptacle outlets rendered not readily accessible by home appliances fastened in place, appliance garages, or home appliances occupying dedicated space shall not be considered as these required outlets. 
  • Exception: To comply with the conditions specified in (á) or (b), receptacle outlets shall be permitted to be mounted not more than 300 mm (12 in.) below the countertop. Receptacles installed below a countertop with this exception shall not indeed be located where in fact the countertop extends a lot more than 150 mm (6 in.) beyond its support bottom. 
  • Lighting + Switching: The entire lighting system is to remain separate from thé 20 amp small appliance circuits. They may occupy the samé multi-gang bóx, but, may not share channels. Lighting circuits are permitted to supply hood fans. 
The spacing for receptacles is called the 2/4 foot rule for outlet spacing on kitchen counters. It’s important to note any package installed under the table on án island and peninsular is required to be a maximum 12 ins below the bár. Furthermore, receptacles are not permitted below shelf if the edge of the table exceeds six is beyond the bottom cabinet. 


Appliances such as ovens and stoves will be cord connected, have got lockout breakers and disconnecting change within sight of systems. Appliances might not be ideal for aluminum conductors. Browse manufacturer's instructions. This might require copper conductors just and terminations accepted for lightweight aluminum or copper. Therefore the discussion about your Kitchen Counter Outlets that I could tell. Probably useful and offer the best alternative for you.